$ Electronic Data Sheet adapted by MMS [File] DescText = "RLWS Configuration"; CreateDate = 10-12-2001; CreateTime = 13:31:30; ModDate = 09-10-2002; ModTime = 15:35:03; Revision = 1.4; $ Release Version 1.4 [Device] VendCode = 742; $ Vendor Code ProdType = 12; $ Product Type ProdCode = 20; $ Product Code MajRev = 1; $ Major Rev MinRev = 1; $ Minor Rev VendName = "Rice Lake Weighing Systems"; ProdTypeStr = "Communications Adapter"; ProdName = "RLWS Communication Interface"; Catalog = "68541"; [IO_Info] Default = 0x0001; PollInfo = 0x0001, 1, 1; Input1 = 8, 0, 0x0001, "Command Response", 6, "20 04 24 64 30 03", " Word 1: Command number\n" " Word 2: Status\n" " Word 3&4: Value"; Output1 = 8, 0, 0x0001, "Command Request", 6, "20 04 24 96 30 03", " Word 1: Command number\n" " Word 2: Parameter\n" " Word 3&4: Value";